8029 PHLOX ST. DOWNEY, CA. 90241 1-800-421-7545
|
|
thompson model vc-454 vacuum/pressure pump CLICK HERE FOR REPLACEMENT PARTS AND KITS
GENERAL DESCRIPTION THE THOMPSON MODEL "VC" 454 CU. IN. PUMP IS AN AIR-COOLED, POSITIVE DISPLACEMENT, RECIPROCATING VACUUM-PRESSURE PUMP DESIGNED TO OPERATE AT CONTINUOUS HIGH VACUUM AND PRESSURE WITHOUT OVERHEATING. THE THOMPSON MODEL "VC" VACUUM-PRESSURE PUMP INCORPORATES A STANDARD CHEVROLET ENGINE SHORT BLOCK, CONVERTED TO ACCEPT OUR SPECIALLY ENGINEERED HEADS, VALVES AND ACCESSORIES. THE EFFICIENT LUBRICATION SYSTEM, STANDARD WITH THE ENGINE BLOCK, GIVES EXCELLENT PROTECTION AGAINST CORROSION AND OVERHEATING. THIS ALSO PROVIDES A LOWER END, CONSIDERABLY MORE DURABLE THAN OTHER PISTON-TYPE PUMPS. THE PUMPS' SIZE AND SHAPE IS SUCH THAT IT WILL READILY MOUNT ON THE SIDE OF A TRUCK CHASSIS OR ON A PLATFORM IN FRONT OR UNDERNEATH A SEMI-TRAILER.
VC-454 WITH SIDE-MOUNT PLATES CLICK HERE FOR FOR VC-454 W/ DIESEL DRIVE & PLATFORM MOUNT Benefits - Over 30 years of leadership in the vacuum pump field - Built-in reliability - Engineered for durability - Standard of the industry - Easy accessibility to low-cost replacement parts - Oil Recirculation - Rebuilding by any mechanic - Multiple methods of mounting - More efficient with less H.P. - Continuous duty
SHIPPING WEIGHTS - Approximately 425 lbs. (WITHOUT MOUNTING HARDWARE)
DIMENSIONS - LENGTH 28" - WIDTH 27" - HEIGHT 27"
NO. 1129 SEPARATOR - SILENCER 1. Drain off accumulated condensate and contaminates, particularly in the morning before starting operations and at the close of each shift. Use drain valve on bottom of separator. NOTE: 1129 Separator should be drained after each operator.
PUMP DRIVE ASSEMBLY 1. A new installment must be checked after four (4) hours of operation. After initial service, check again after twelve (12) hours.
A. Driveline companion flanges keys and set screws. B. Bearing set screws and mounting bolts. C. Sheave bushings, keys and set screws. D. Sheave alignment. E. V-belt tension (3/8" deflection) and wear. NOTE: If necessary, replace all belts using a matched set. F. Flexible coupling (as per manufacturer's recommendations). G. Pump mounting and manifold bolts. NOTE: During initial operation, (harmonics and vibration), consistently loosen set screws and bushings. If not serviced expensive damage may occur.
TORQUE SPECIFICATIONS FOR PUMP DRIVE ASSEMBLY Set screws -- 120 ft. lb.
Drive line nuts and bolts -- 80 ft. lb.
|
|